Portable Medical Syringe Pump with Voice Alarm System and Drug Bank

Product Information:hospital Surgical Instruments Syringe Infusion Pump medical equipment (SLV-S820)Features:1. HD LCD Display, high capacity words, friendly user interface, dynamically displayworking status;2. Audible and visual alarm for There are bubbles,Tube is blocked,Close the door,IV setMismatched , Battery running out ,

Featured Products

Product Information:hospital Surgical Instruments Syringe Infusion Pump medical equipment (SLV-S820)
Features:
1. HD LCD Display, high capacity words, friendly user interface, dynamically display
working status;
2. Audible and visual alarm for There are bubbles,Tube is blocked,Close the door,IV set
Mismatched , Battery running out , Infusion finish , Equipment failure , Abnormally
Operation,Software Exception,Low battery,forget the operations etc;
3. Compatible with any brands of infusion sets after correct calibration;
4. Preset solution volume to greatly reduce the workload of nurses;
5. Work mode: ml/h and drop/min can switch freely;
6. Three levels of occlusion: high, middle and low;
7. Purge function;
8. KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is
1ml/h---5ml/h (1ml/h step);
9.Power Source:100-240Vac, 50/60Hz; Internal rechargeable Li battery,
capacity≥1,800mAh, voltage=11.1V, 4 hours backup time at the rate of 25ml/h (appointed
medium rate in IEC60601-2-24) for the new battery charged for 12hours;
10. Automatically record the settings of last infusion;

Portable Medical Syringe Pump with Voice Alarm System & Drug Library
Portable Medical Syringe Pump with Voice Alarm System & Drug Library
Portable Medical Syringe Pump with Voice Alarm System & Drug Library
Portable Medical Syringe Pump with Voice Alarm System & Drug Library


 

Specifications

Infusion Rate

ml/h mode: 1~1200ml/h (1ml/h step)

drop/min mode: 1~266drop/min (1drop/min step)

Purge Rate

100ml/h---1200ml/h (can be calibrated)

Flow Rate Accuracy

ml/h mode: Within ±5% (after correct calibration)

drop/min mode: Within ±3% (after correct calibration)

Mechanical Precision

Within ±2%

Maximum infusion pressure

150kPa

KVO Speed

1ml/h---5ml/h (1ml/h step)   

Volume Limit

1ml---9999ml

Total Infusion Volume

0---9999.9ml

Alarm Pressure

 

 

 

High 800mmHg±200mmHg (106.7kPa±26.7kPa)

Medium 500mmHg±100mmHg (66.7kPa±13.3kPa)

Low 300mmHg±100mmHg (40.7kPa±13.3kPa)

Audible and Visible Alarms

There are bubbles, tube blocked,  door closed, IV set Mismatched, battery running out, infusion finish, equipment failure , abnormally operation, software exception, low battery, forget operations, etc.

Bubble Detector

Ultrasonic wave detector; detection sensitivity ≥25μL

Forbidden

Not support blood Infusion  

   

Transport & Storage Condition

Temperature: -20ºC~+55ºC

Relative Humidity:  ≤95%

Atmospheric Pressure: 50.10KPa---106.0KPa


Portable Medical Syringe Pump with Voice Alarm System & Drug Library
Portable Medical Syringe Pump with Voice Alarm System & Drug Library
Portable Medical Syringe Pump with Voice Alarm System & Drug Library
Portable Medical Syringe Pump with Voice Alarm System & Drug Library
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours